INSTALLATION AND OPERATING INSTRUCTIONS
VARI-PAK
CYCLING DC MOTOR CONTROL
Designed for Indexing Applications –
© 2003 KB Electronics, Inc.
OLSTOPON
JOG / STOP
RUN
DC MOTOR SPEED CONTROL
VARI-PAK
NEMA-12
100
90
80
70
60
40
30
20
10
0
50
%
144 S. Wolf Rd
Wheeling, IL 60090
(847) 459-5200
See Safety Warning on Page 2
The information contained in this manual is intended to be accurate. However, the manufacturer
retains the right to make changes in design which may not be included herein.
This manual covers the following CAMCO part numbers:
92A61633010000, 92A61633020000, 92A61633030000, 92A61633040000
Industrial Motion Control, LLC
Vista de página 0
1 2 3 4 5 6 ... 23 24

Resumo do Conteúdo

Página 1 - VARI-PAK

INSTALLATION AND OPERATING INSTRUCTIONSVARI-PAKCYCLING DC MOTOR CONTROL– Designed for Indexing Applications –© 2003 KB Electronics, Inc.OLSTOPONJOG /

Página 2

8II. MOUNTINGMount the control in a vertical position on a flat surface. Be sure to leave enough room belowthe bottom of the control to allow for the

Página 3 - JUMPER J1 SETTING vs

Failure to follow the Safety Warning Instructions may result in electric shock, fire or explosion.Do not fuse neutral or grounded conductors. Note: S

Página 4

1. Remote Potentiometer. Connect remotepotentiometer wires to terminals P1, P2and P3, so that the “high” side of thepotentiometer connects

Página 5 - TABLE 1 – ELECTRICAL RATINGS

B. ”JOG” (Stop) – A maintained contactclosure between terminals “JOG” and“RTN” will cause the control to runcontinuously. This is not a l

Página 6

12E. +24 VDC SUPPLY – The +24V terminal provides a nominal124 VDC @ 12 mA output foruse with an external load such as one solid-state 3-wire proximity

Página 7 - L2L1A2A1

13Capable of switching 30 VDC, at 24 mA,with an off-state leakage current of lessthan 1 mA. (See figure 12.) Warning!Do not ground or short +24V to

Página 8

14The “Cycle on Demand” function isrequired for most indexing table applica-tions. The control can be easily set forthis operation as follows:1. Jump

Página 9

15VIII. APPLICATION WIRING DIAGRAMS (Reversible Models)P/N 92A61633020000 (120 VAC) – P/N 92A61633040000 (240 VAC).Reversing models carry out the same

Página 10 - MOTOR HORSEPOWER

16After the control has been set up properly (the jumpers set to the desired positions and thewiring completed), the start-up procedure can begin. I

Página 11 - A1 A2 L1 L2

WARNING! Do not adjust trimpots with main power on if possible. If adjust-ments are made with power on, insulated adjustment tools must be used and

Página 12 - See section IV

TABLE OF CONTENTSSection Pagei. Simplified Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 13 - RUN JOG STP RTN +24V COM

C. Overload Indicator (OL) – When the motor is loaded to the current limit setpoint (CL set-point is established by the setting of jumper J1 and th

Página 14 - "O""F"

XII – TROUBLESHOOTING GUIDEMOTOR WILL NOT RUN:1. Check control operation by placing RUN - JOG/STOP in RUN position.2. Make sure disconnect fuses or ci

Página 15 - FIGURE 14A – ROLLER GEAR UNIT

20NCSTOPJWCON1 CON2P3P2P1RSJOG FWDRUN FWDJOG REVRUN REV(8)(7)(6)(5)MIN MAX CL IR10ANOJ13.3A2A5ATB1(2)(4)RTN(3)+24VFCOMOJRRB1RB2JS180V90VJ3KBPI 120V240

Página 16

– NOTES –21

Página 17

(A40290) – Rev. H – 7/2003INDUSTRIAL MOTION CONTROL, LLC1444 SOUTH WOLF ROADWHEELING, IL 60090 USATel: 847-459-5200 Toll-Free: 800, 645-5207

Página 18 - LS2 (N/O)

i. SIMPLIFIED OPERATING INSTRUCTIONSA. AC Power – Use 120Volt AC rated controls on120 Volts AC and 240Volt AC rated controls on240 Volts AC.

Página 19

I. INTRODUCTIONThe VARI–PAK Series is housed in a rugged die cast aluminum NEMA 12 enclosure. Thecontrols are designed specifically for cycling and i

Página 20

392A61633040000Logic ProvidedType ofOperationMaximumHorsepowerHP, (kW)Maximum DCLoad Current(DC Amps)Maximum ACLoad Current(RMS Amps)Motor ArmatureVo

Página 21

4—Specifications SpecificationsFactorySettingFactorySettingPart Nos. Part Nos.Parameter(Units)AC Line Input(VAC ± 10%, 50/60 Hz)92A6163301000092A61633

Página 22 - KBPI RELAY

5RB2 RB1P1 P2 P3CON1120VL2L1A2A1TB2J2B J2ARSJWCON2240VMIN MAX CL IRP4J390V 180VJSNC NO3.3AJ12AKBPI 10A5AOFJRTB1(3)(2)COM(1)+24V(6)JOG FWDSTOPRTN(4)(5)

Página 23 - – NOTES –

6RB2 RB1(6)(2)(1)COMJROFTB1+24V(3)RTN(4)(5)JOG FWDSTOPP1(7)(8)RUN REVJOG REVRUN FWDP2 P3CON1120VL2L1A2A1TB2J2B J2A5A2A3.3A10A90VJ3180VNCJSNOKBPI RSJWC

Página 24 - WHEELING, IL 60090 USA

7FIGURE 3 – MECHANICAL SPECIFICATIONS (Inches / [mm])RECOMMENDED MOUNTING SCREW: 1/4" (M6)[127.00]5.000[138.99]5.472[149.50]5.886[9.07]0.357[208.